Bacula device has 0 slots

Unable to label tapes in bacula - Spiceworks Community Forgot to include changer device directive under tape drive declarations in bacula-sd.conf. Even through I had the changer device declarations, I needed to add them to the tape drive declarations as well. Durr! Bacula update slots scan free roulette

Apr 15, 2015 ... Bacula is an open-source network backup solution that allows you create ... performs reads and writes on the storage devices used for backups ... Bacula has several components that must be configured independently in order to function correctly. ..... Sending label command for Volume "MyVolume" Slot 0 . Storing Backups to the Oracle Cloud – Storage / Archive Classic - bacula ... auth = https://bacula.br.storage.oraclecloud.com/auth/v1.0 auth_token = AUTH_xxxx ... Add a device similar to the Bacula Storage Daemon Configuration file ... If you are using Archive Storage that has a latency of a few hours to restore (similar ... There's a soft-coded limit of 8192 tape “slots” in rclone-changer but this can ... Bacula backup server on Debian Lenny, with remote SQL server ... Nov 6, 2010 ... Examples may be indexes of files for a backup that has been run, the state of the media .... Device { Name = FileStorage; Media Type = File; Archive Device ..... label storage=MHVTL drive=0 pool=Scratch slots=1-22 barcodes. Please help - cannot label a tape - Google Groups

Vol=OffsiteCloudFull0000 Slot=0 VolType=0 server-sd: dev.c:506-207676 Notify ... or destination > storage/volumes, and it doesn't seem to ask what cloud device it ... If I try to upload a volume to the cloud through bconsole, it says "Volume has  ...

May 04, 2013 · Hello, First of all, here's the setup for my Bacula server: Dell PowerEdge R320 server Dell PowerVault 124T LTO5 tape changer FreeBSD 9.1 OS... Re: [bacula-brasil] Bad autochanger "loaded? drive 0 Feb 10, 2016 · Sending label command for Volume "A00041" Slot 3 3304 Issuing autochanger "load slot 3, drive 0" command for vol A00041. 3992 Bad autochanger "load slot 3, drive 0": ERR=Child died from signal 15: Termination. Results=Program killed by Bacula (timeout) Meu SD está na mesma máquina do DIR conf do SD # # An autochanger device with two drives # Adding a tape library to BaculaDan Langille's Other Diary This article was written some months go, but only published today. I recently acquired a new tape auto-changer / library. I have already run some simple tests on the library, and all seems well. I already have an existing Bacula installation and my plan is to add this new auto-changer into that.

Bacula device autochanger has 0 slots - Big fish casino slot tournaments - Horaire tournois poker casino montreal. Greater Ancestors Bacula device autochanger has 0 slots - Big fish casino slot tournaments - Horaire tournois poker casino montreal ...

Hello Distribution: Ubuntu 12.04 Issue: Bacula does not properly recognize the 12 tape slots of the ADIC-1200 G. Details: 1) *update slots scan 3306 Issuing autochanger "slots" command. Device "AutoChanger1" has 0 slots. No slots in changer to scan. 2) If I start bacula-sd directly, it works # service bacula-sd stop * Stopping Bacula Storage ... Bacula Slots Scan - playonlineslotcasino.loan Device Yam-TTO-5-Changer has 23 slots.Results=Program killed by Bacula (timeout) No VolName for Slot=3 InChanger set to zero. Connecting to Storage daemon TapeLibrary at 10.1.1.30:9103... 3307 Issuing autochanger unload slot 2, drive 1 command. 3304 Issuing autochanger load slot 2, drive 0 command. 3992 Bad autochanger load slot 2, drive 0: ERR ...

I am using Bacula 3.0.2 ... at scbus1 target 5 lun 0 (sa0,pass0) at ... hardware has moved to new logical devices.

Description of problem: bacula-sd reports "Permission denied" on the device though it runs as root and all the devices are read-/writable for root. When trying to read the tape barcode labels, 0 slots instead of 40 are detected. But if one simply copies and renames the init script, everything works fine. Adding a tape library to Bacula – Dan Langille's Other Diary Device "DTL01" (/dev/nsa0) open but no Bacula volume is currently mounted. Slot 5 is loaded in drive 0. Total Bytes Read=0 Blocks Read=0 Bytes/block=0 Positioned at File=0 Block=0 Device "DTL02" (/dev/nsa1) open but no Bacula volume is currently mounted. Slot 2 is loaded in drive 0. Bacula Relabel Tape – Riaan's SysAdmin Blog Some notes on what I did to erase a tape in Bacula. unmount using bconsole *unmount The defined Storage resources are: 1: File 2: Scalar Select Storage resource (1-2): 2 3307 Issuing autochanger "unload slot 2, drive 0" command. Update Slots Scan Bacula - raffaeleruberto.com

Bacula won't make use of 2 tape devices simultaneously. (Search for #-#-# for the TL;DR) A little background, perhaps. In the process of trying to get a decent ...

Hello, First of all, here's the setup for my Bacula server: Dell PowerEdge R320 server Dell PowerVault 124T LTO5 tape changer FreeBSD 9.1 OS...

I have done this serval times, but no luck. The update command shows the correct volumes. *update slots storage=TL4000-Storage drive=0 Connecting to Storage daemon TL4000-Storage at bacula.example.com:9103 ... 3306 Issuing autochanger "slots" command. Device "TL4000" has 47 slots. Bacula / Thread: [Bacula-users] bacula does not recognizes ... Hello Distribution: Ubuntu 12.04 Issue: Bacula does not properly recognize the 12 tape slots of the ADIC-1200 G. Details: 1) *update slots scan 3306 Issuing autochanger "slots" command. Device "AutoChanger1" has 0 slots. No slots in changer to scan. 2) If I start bacula-sd directly, it works # service bacula-sd stop * Stopping Bacula Storage ... Bacula Slots Scan - slotbonuswincasino.loan Device Autochanger has 0 slots. No slots in changer to scan.Bacula Console and Operators Guide. ... If you do not have barcodes, you can accomplish the same thing in version 1.33 and later by using the update slots scan …Play Mystic Millions, Space Girls, or Muses of Terra.